FAQ Peridect+ Underground

SOLUTION

  • Yes, you can. DSP+ (fence) and DSP+/U (underground) detectors can be connected to the same LCP+.

SOLUTION

  • A connected line is laid directly into the ground to a depth of 40 cm while in normal cases there is no need for special landscaping. The detectors have to be positioned flatwise with the larger base surface upwards.
  • In some specific environments (heavily waterlogged clay soil) may be suitable, in addition to a shorter distance between the detectors, to dig the detectors in closer to the surface.
  • Special attention should be paid to installations near trees, bushes, canals, etc.
  • Installation under asphalt or concrete is not recommended.
  • The top of the corridor can be filled with the material that transmits vibrations to increase sensitivity.
  • At very high requirements for reliability of detection it is possible to create a corridor with a width of about 80 cm with a material that transmits vibrations well, typically round stones or grit.